Fluke 117 True RMS Multimeter with Non-Contact Voltage
Fluke 117 True RMS Multimeter with Non-Contact Voltage
$289.99
NIST Calibration certificate included!
View our Certificate of Accreditation here.
- Compact, true-rms digital multimeter for electricians
- Includes multimeter, 4mm silicone test leads, holster and manual
- Integrated non-contact voltage detection keeps you safe
- Prevent false readings from ghost voltage with selectable low-impedance mode
Available on backorder
Technical Specs
- Maximum voltage between any terminal and earth ground: 600 V
- Safety IEC 61010-1: Pollution Degree 2
- IEC 61010-2-033: CAT III 600V
- Fuse for A input: 11 A, 1000 V FAST Fuse (Fluke PN 803293)
- Display Digital: 6,000 counts, updates 4 per second
- Bar graph: 33 segments, updates 32 per second
- Operating temperature: -10°C to +50°C
- Storage temperature: -40°C to +60°C
- Battery type: 9 volt Alkaline, IEC 6LR61
- Battery life: 400 hours typical, without backlight
Accuracy Specifications
- DC millivolts: Range/resolution 600.0 mV / 0.1 mV. Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- DC volts: Range/resolution 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V. Accuracy: ±([% of reading] + [counts]): 0.5% + 2
- Auto volts: Range/resolution 600.0 V / 0.1 V. Accuracy: 2.0% + 3 (DC, 45 Hz to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
- AC millivolts¹ True RMS: Range/resolution 600.0 mV / 0.1 mV. Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- AC volts¹ True RMS: Range/resolution 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V. Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
- Continuity: Range/resolution 600 Ω / 1 Ω. Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
- Ohms: Range/resolution 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ6.000 MΩ / 0.001 MΩ. Accuracy: 0.9% + 1. Range/resolution 40.00 MΩ / 0.01 MΩ. Accuracy: 5% + 2
- Diode test: Range/resolution 2.00 V / 0.001 V. Accuracy: 0.9% + 2
- Capacitance: Range/resolution 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF. Accuracy: 1.9% + 2. Range/resolution > 1000 μF. Accuracy: 5% + 20%
- Lo-Z capacitance: Range 1 nF to 500 μF. Accuracy: 10% + 2 typical
- AC amps True RMS (45 Hz to 500 Hz): Range/resolution 6.000 A / 0.001 A, 10.00 A / 0.01 A. Accuracy: 1.5% + 3. 20 A continuous overload for 30 seconds max
- DC amps: Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A. Accuracy: 1.0% + 3. 20 A continuous overload for 30 seconds max
- Hz (V or A input)²: Range/resolution 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.1 Hz, 9.999 kHz / 0.001 Hz, 50.00 kHz / 0.01 Hz. Accuracy: 0.1% + 2
- All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
- Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
- Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
- Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
- Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
- Weight 550 g
Additional information
Weight | 5 lbs |
---|